HVAC ResVent 62.2‎

ResVent 62.2 allows you to quickly perform comprehensive whole-building ventilation requirements for residential buildings following the most recent versions of these important standards, ASHRAE 62.2-2007 and 62.2-2010, for both new and existing dwellings.
First published in 2003, ANSI/ASHRAE 62.2, Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings, sets minimum requirements for whole-building and local (bathrooms and kitchens) ventilation rates for dwellings.
ASHRAE 62.2 . . . “applies to spaces intended for human occupancy within single-family houses and multi-family structures of three stories or fewer above grade, including manufactured and modular houses.” (ASHRAE 62.2-2007 and 62.2-2010, page 2.)
Features
· Math-on-the-Fly, allowing you to calculate results within an input box, for example, you can calculate volume by entering 40*25*8. Press “Done” and the answer appears in the input box! You may use addition, subtraction, multiplication, division, or exponents.
· Reporting feature allows you to e-mail a report of your entries and results back to your office or to the client.
· The weather factors – over 200 – for the U.S. and Canada are included on a picker list for easy selection. These factors are from ASHRAE Standard 136, A Method of Determining Air Change Rates in
Detached Dwellings.
· Slider controls for the easy entry of most data. The slider controls allow you to quickly perform “what-if” analysis, such as finding the measured leakage rate at which the whole-building
ventilation requirement becomes zero. You can set the slider control ranges.
· Whole-building mechanical airflow requirement result is displayed on each input screen so you can view the instantaneous result of your input changes.
· Fan Run-Time Tool for finding the number of minutes per hour your whole-building fan must operate.
· Calculation of the infiltration credit for Standards 62.2-2007 and 62.2-2010 using ASHRAE Standards 119, Air Leakage Performance for Detached Single-Family Residential Buildings; and 136, A Method of Determining Air Change Rates in Detached Dwellings. The infiltration credit is needed for determining the whole-building ventilation rates in existing dwellings.
· Alternative Compliance Tool allows you to determine the alternative compliance supplement used for existing dwellings when using Standard 62.2-2010. You may select up to five bathrooms for this
procedure. This compliance path is found in Appendix A of the 62.2-2010 standard.
· When creating a new project, you may use the included default project or any other existing project as the basis for your new one. The number of projects is only limited by the memory of your hardware.
· The global settings allow you to choose ASHRAE 62.2-2007 or ASHRAE 62.2-2010 for complete whole-building ventilation compliance with either. You may also select IP or SI units for your calculations.
· A full report of your entered data and results may be e-mailed from your iPhone, iPod, or iPad.
· Includes a comprehensive help screen.
 

Psychrometer

Psychrometer is an application to calculate the various properties of moist air. You can easily calculate values such as dew point temperature and relative humidity. To calculate the water vapor pressure, we use the Tetens(1930) equation. 
Features:
– Intuitive operation of slider.
– Temperature units, Celsius (℃) and Fahrenheit (℉).
– Volumetric humidity units, (g/m³) and (gr/ft³).
– Specific humidity units, (g/kg) and (gr/lb).
– Pressure units, (hPa), (mmHg) and (inHg).
– Enthalpy units, (kJ/kg) and (Btu/lb) .
– Specific volume units, (m³/kg) and (ft³/lb).
– There are two types of psychrometers, natural and forced ventilation.
The value can be computed:
Relative humidity, Discomfort index, Volumetric humidity, Specific humidity, Vapor pressure, Saturation vapor pressure, Dew point temperature, Enthalpy, Specific volume.
 

Hygrometer

Hygrometer is a application for all models of iphone or ipod touch that
display the outdoor relative humidity. `
The value is displayed as a percentage.
A internet connexion is needed to retrieve the humidity from our weather
server with the the latitude and the longitude.
 
http://itunes.apple.com/nl/app/hygrometer/id341151288

wet-bulb‎

Wet bulb calculator
Developed by TechnoAlpin, dv media, app-factory, Gabriel Gritsch Software Development
Wat is nieuw in versie 2.0:
New design, new temperature (+1° C, +2° C / +34° F, +36° F) 
 
http://itunes.apple.com/nl/app/wet-bulb/id405219167

KEA‎ – Keep an Eye on your Air!

Monitor your Indoor Air Quality with Sens-Innov sensors!
This app allow you to monitor your indoor air parameters like Temperature, Humidity, Luminosity, Carbon Dioxyde Rate, Volatile Organic Compounds Rate, Formaldehyde and so on. Please visit www.sens-innov.com to see all measurable parameters.
This app is coupled with Sens-Innov Sensors and displays in different ways informations issued from these sensors.
To enter the app you need an identifier, a password and a server address. All these informations are provided by Sens-Innov. To get these informations please contact Sens-Innov via our web site : www.sens-innov.com



http://itunes.apple.com/nl/app/kea/id435084127